What is ESR METER ?

Written by Jestine Yong


Continued from page 1

» Low ohms resistor such as 0.22 ohm, 0.33 ohm and etc. » Horizontal yoke coil winding of a picture tube, inductor and primary winding of a transformer – If a shorted turn is present,repparttar inductance drops dramatically andrepparttar 138979 meter will showrepparttar 138980 ohms reading. » Horizontal output transistor (HOT) in a monitor or TV – If an open-circuit reading is obtained,repparttar 138981 short-circuit is elsewhere. Ifrepparttar 138982 short-circuit remains,repparttar 138983 transistor is faulty. » Short-circuit inrepparttar 138984 track, usually trace torepparttar 138985 components - You can userepparttar 138986 ESR meter to locate short-circuits on printed circuit boards by measuringrepparttar 138987 actual track resistance. Ifrepparttar 138988 reading increases as you probe further alongrepparttar 138989 track, you know you’re going inrepparttar 138990 wrong direction! » Speakers, amplifier etc - The pulses have a fast rise/fall time, so it would probably make a crude RF signal injector as well. » The condition of bothrepparttar 138991 normal and rechargeable batteries – Flat and faulty battery will have high ESR.

Jestine Yong is a electronic repairer and a writer. For more repair information, please visit http://www.noahtec.com


What is a Fuse ? And how to test it.

Written by Jestine Yong


Continued from page 1

Is some cases a fuse will open up fast enough when there is a surge so that other components aren’t damaged. If this isrepparttar case, replacingrepparttar 138978 fuse with one ofrepparttar 138979 same type and rating restores operation. Unfortunately, a high probability exists that if a fuse blew, something inrepparttar 138980 circuit it was protecting shorted out. In this case, a replacement fuse blows right away. The blown fuse can easily be replaced by a new one, afterrepparttar 138981 overload has been eliminated when come into replacement. Use onlyrepparttar 138982 same current and voltage ratings asrepparttar 138983 original. The common type and current rating of a fuse in a monitor are slow blow 2A to 5A. When you buy replacement fuses, get several – you can easily use all of them while you’re troubleshooting an elusive problem.

Testing Fuses

Turnrepparttar 138984 power off and removerepparttar 138985 fuse fromrepparttar 138986 circuit to check with a multimeter set torepparttar 138987 lowest ohms range. Connectrepparttar 138988 probes to both end ofrepparttar 138989 fuse. You may checkrepparttar 138990 fuse while it still in circuit. A good fuse should showed continuity or read 0 ohm. A blown fuse is open which reads infinity onrepparttar 138991 meter.



Jestine Yong is a electronic repairer and a writer. For more repair information, please visit http://www.noahtec.com


    <Back to Page 1
 